RDL-2000 Installation Guidelines
70-00144-01-01 Proprietary Redline Communications © 2011 Page 37 of 52 March 9, 2011
Weatherproof LP Connections
It is important to weatherproof both ends of the line protection unit.
1. Begin to wrap the splicing tape. Start as close to the LP housing as possible. Stretch
and wind the tape back along the connector housing making very sure there are no
gaps in the tape.
Figure 25: LP Ethernet Cable Entry Weatherproofing - Pt-1
2. Continue to wrap the tape tightly along the cable.
Figure 26: LP Ethernet Cable Entry Weatherproofing - Pt-2
3. Work the mastic putty into the area between the connector and the body of the LP.
Continue to work the putty in making a watertight seal. The connection is now well
weatherproofed.
Figure 27: LP Ethernet Cable Entry Weatherproofing - Pt-3
Repeat this procedure for both cable connections to the LP.